Autoclave Engineers 280mL Autoclave

Equipment Information: 316 s/s construction; capacity: 0.0739 gallons; 3in. D x 2in. deep; 3in. D carberry spinning basket agitator with top and bottom props under driven by .25hp DC 2,500rpm motor thru Magna drive agitator drive, rated 2,450psi @ 650F degrees; electrically heated with 3 zones, two 1,100 watt, one 800 watt heater bands

Full specifications
Equipment Information
316 s/s construction; capacity: 0.0739 gallons; 3in. D x 2in. deep; 3in. D carberry spinning basket agitator with top and bottom props under driven by .25hp DC 2,500rpm motor thru Magna drive agitator drive, rated 2,450psi @ 650F degrees; electrically heated with 3 zones, two 1,100 watt, one 800 watt heater bands
Condition
used/preowned
Used / Pre-owned#f45743

Autoclave Engineers 2,000mL Reactor

Equipment Information: 316 s/s construction; capacity: 0.528 gallons; approximate 4in. D x 8in. straight side; bolted top; dish bottom; rated 3,300psi at 850F internal; jacketed chamber with Magna drive agitator with mechanical seal

Full specifications
Equipment Information
316 s/s construction; capacity: 0.528 gallons; approximate 4in. D x 8in. straight side; bolted top; dish bottom; rated 3,300psi at 850F internal; jacketed chamber with Magna drive agitator with mechanical seal
Condition
used/preowned/built
Used / Pre-owned#ae45141014

Direct Steam Injection Sterilization System

Equipment Information: 65gpm; vacuum thermal instant sterilization (VTIS) is designed to sterilize fermentation media at temperatures up to 290F for 20 second hold time; product is pre-heated to 175F before going into the Hydrothermal steam injector; steam injector puts steam in direct contact with the product and then it goes into the flash chamber, which removes the extra water added from the condensed steam; sterilized product is cooled to the final temperature in the regeneration heat exchanger section; upon exiting the regeneration section, the product goes from the VTIS skid to the fermenter; button control with viewing screen

Full specifications
Equipment Information
65gpm; vacuum thermal instant sterilization (VTIS) is designed to sterilize fermentation media at temperatures up to 290F for 20 second hold time; product is pre-heated to 175F before going into the Hydrothermal steam injector; steam injector puts steam in direct contact with the product and then it goes into the flash chamber, which removes the extra water added from the condensed steam; sterilized product is cooled to the final temperature in the regeneration heat exchanger section; upon exiting the regeneration section, the product goes from the VTIS skid to the fermenter; button control with viewing screen
Condition
used/preowned
Used / Pre-owned#f2658-1

Getinge 433HC Autoclave

Equipment Information: s/s chamber, approximately 17.5in. x 17.5in. x 27in. deep chamber; rated 45psi at 300F degrees internal; jacketed for 45psi at 300F degrees: touch pad with viewing screen and meter controls; National Board #5609; electrical: 115v/50-60hz/12 amps

Full specifications
Equipment Information
s/s chamber, approximately 17.5in. x 17.5in. x 27in. deep chamber; rated 45psi at 300F degrees internal; jacketed for 45psi at 300F degrees: touch pad with viewing screen and meter controls; National Board #5609; electrical: 115v/50-60hz/12 amps
Condition
used/preowned/built 2004
Used / Pre-owned#3415-2

ICOS AV Series Pass-Thru Autoclave

Equipment Information: s/s construction, approximately 250 cubic feet chamber; chamber dimensions: 49.5in. W x 129.5in. L x 67.5in.H; internal and jacket certified at 36.3psi at 284F degrees; internal vacuum rated; Finder liquid ring vacuum pump; National Board #270; motor: 20hp, 1,764rpm; electrical: 480v/28.1 amps

Full specifications
Equipment Information
s/s construction, approximately 250 cubic feet chamber; chamber dimensions: 49.5in. W x 129.5in. L x 67.5in.H; internal and jacket certified at 36.3psi at 284F degrees; internal vacuum rated; Finder liquid ring vacuum pump; National Board #270; motor: 20hp, 1,764rpm; electrical: 480v/28.1 amps
Condition
used/preowned/built 2005
Used / Pre-owned#a2933

Rodwell Gemini Scientific Autoclave

Equipment Information: comes with upper and lower working chambers with 158 L each capacity; unit is electrically heated; design pressure: 2.62bar; design temperature: 138 degrees C; hyd.test press: 4.14 bar; electrical: push button controls with viewing screens; 480v/3ph/60hz/19kw

Full specifications
Equipment Information
comes with upper and lower working chambers with 158 L each capacity; unit is electrically heated; design pressure: 2.62bar; design temperature: 138 degrees C; hyd.test press: 4.14 bar; electrical: push button controls with viewing screens; 480v/3ph/60hz/19kw
Condition
used/preowned/built 2013
Unused#ae52952001

Steris Amsco Centruy Series Sterilizer (unused)

Equipment Information: 15gpm; single quick open door; chamber size: W 34in. x H 52in. x D 66in. with prevac; chamber and jacket rated 45psi at 20 to 300F degrees; Allen-Bradley Logic 53 PLC controls with Allen-Bradley Panelview 600 HMI; mounted on a carbon steel frame with casters; driven by 2hp, 3,450rpm motor through a reducer; E-Stop button; electrical: 208-240-460v/3ph/60hz/45psi; never installed into production

Full specifications
Equipment Information
15gpm; single quick open door; chamber size: W 34in. x H 52in. x D 66in. with prevac; chamber and jacket rated 45psi at 20 to 300F degrees; Allen-Bradley Logic 53 PLC controls with Allen-Bradley Panelview 600 HMI; mounted on a carbon steel frame with casters; driven by 2hp, 3,450rpm motor through a reducer; E-Stop button; electrical: 208-240-460v/3ph/60hz/45psi; never installed into production
Condition
unused/built 2003
Used / Pre-owned#f2929-9

Tuttnauer EZ10k Autoclave

Equipment Information: chamber 10in. x 19in.; touch screen controls with digital viewing screen

Full specifications
Equipment Information
chamber 10in. x 19in.; touch screen controls with digital viewing screen
Condition
used/preowned